Victorian terraces often combine solid walls, single glazing and narrow rear gardens, so a retrofit has to solve two problems at once: cut heat demand and fit a low-carbon source into a plot only 4–5 metres wide. A typical three-bedroom terraced house may need 6–8 kW at design conditions before fabric upgrades. After loft insulation, cavity fill where possible, and draught-proofing, that figure can fall, but the remaining load still has to be met on the coldest days.
The cause: why one air-source unit per house struggles
An air-source heat pump needs clear space for airflow and a buffer from neighbouring bedrooms; on a narrow terrace, the available wall often sits beside a shared passage or beneath a first-floor window. Defrost cycles, compressor noise and planning limits make tightly packed installations difficult. Electrical capacity is another bottleneck: several 8 kW units on one street can trigger a supply upgrade, and each unit still needs its own outdoor space, condensate route and service access.
The solution: a shared loop with a bananzia layout
The bananzia approach treats the block rather than the house as the unit of design. Six to eight terraced homes share a ground loop, with shallow horizontal trenches or compact boreholes placed under a communal path, parking bay or rear access strip. Each home keeps its own heat pump and controls, but the outdoor plant is concentrated in a small manifold or plant room, reducing visual clutter and service visits.
In a typical terrace, a shared loop can cut outdoor unit count from eight to one or two central plant items, while leaving each household with a familiar thermostat and hot-water schedule. The design also separates the noisy part of the system from bedroom walls and keeps gardens usable.
What the install involves
Survey the block for trench routes, service crossings and tree roots before fixing loop length.
Group homes by heat demand and occupancy pattern so the loop is not oversized for low-use households.
Keep flow temperatures low with larger radiators or underfloor emitters; a shared loop does not fix undersized heat emitters.
Meter each dwelling’s heat draw and electricity use so running costs remain transparent.
The result: lower disruption, clearer handover
For residents, the practical gain is less disruption per home: one trench campaign instead of eight separate garden digs, and fewer outdoor units to maintain. For installers, the gain is a repeatable block-level design with known pipe routes and shared commissioning checks. The main risk is coordination; a shared loop still needs clear ownership, access agreements and a maintenance plan before the first trench is opened. Where those are settled, bananzia-style shared loops give terraced streets a realistic route to low-carbon heat without sacrificing the back garden.